HiCO.CAN-104-2HV

Aktive CAN Karte mit PC/104 Stecker

Mit zwei galvanisch getrennten CAN Kanälen (bis 3kV) und Timestamps mit 10µs Auflösung. Treiber für Windows, Linux und QNX verfügbar.



Special Functions
2 x CAN-channel with SJA1000 or TJA 1040 CAN Controller
Local controller 68332G processor, 20 MHz
Physical connection to CAN via 82C251 high-speed CAN transceivers
Electrical isolation up to 3kV (for e.g. medical applications) (CAN nodes galvanically isolated from the control and from each other)
Resources setup via jumpers
Baud rate up to 1MBaud
100% bus load
Supports CAN 2.0A, CAN 2.0B, CANOpen
Timestamps with 10-µs resolution
Internal receive queues with 2048 telegrams each
also available as a Fault-tolerant variant

Operating temperature
0°C – 70°C
-40°C – 85°C (erweitert)

Name Zusammenfassung Datei
DOS Driver Manual DOS Driver Manual for HiCOCAN cards
Change date04.08.2017
TypManual
SpracheEnglish
DOS Sources DOS Sources for HiCOCAN cards,
no support or development.
Change date04.08.2017
TypDriver
SpracheEnglish
Hardware Manual CAN Hardware Manual for all emtrion CAN cards
Change date04.08.2017
TypManual
SpracheEnglish
Linux 2.6.x driver Linux 2.6.x driver
Change date04.08.2017
TypDriver
SpracheEnglish
Setup Information Setup Information for Windows Driver version 5.3
Change date04.08.2017
TypManual
SpracheEnglish
Software Manual CAN Software manual for all emtrion CAN cards.
Change date10.08.2012
TypManual
SpracheEnglish
Windows Driver Version 5.3 Driver supports the following operating systems: Windows XP 32-bit edition
Change date04.08.2017
TypDriver
SpracheEnglish



For more information on this product, please visit our SupportNet.


Zurück